Standing Pilot Ignition

A.

This appliance has a pilot which must be lighted by hand. When

lighting the pilot, follow these instructions exactly

.

B.

BEFORE LIGHTING smell all around the appliance area for gas.

Be sure to smell next to the floor because some gas is heavier

than air and will settle on the floor

.

WHA

T

T

O

DO IF YOU SMELL

GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your

building.

Immediately call your gas supplier from a neighbor's phone.

Follow the gas supplier's instructions.

If you cannot reach your gas supplier

, call the fire department.

LIGHTING INSTRUCTIONS

1.

T

u

rn wall switch to the "OFF" position or thermostat to the

lowest setting.

2.

Remove control access panel.

3.

T

u

rn manual gas valve to CLOSED. W

a

it five [5] minutes to

clear out any gas. If you then smell gas, ST

OP! Follow "B" in the

safety information above on this label. If you don't smell gas, go

to next step.

4.

T

u

rn gas line to "OPEN".

5.

T

u

rn pilot knob clockwise to "OFF". (Knob may have to be

depressed to pass "PILOT" position.)

6.

Locate pilot assembly inside appliance.

7.

Locate red ignitor button.

8.

T

u

rn pilot knob to "PILOT" and push in.

9.

Continue to hold in pilot knob and push the red ignitor button

12-15 times until small blue pilot flame appears.

10.

Continue to hold in pilot knob for approximately one minute. Pilot

should remain lit. If pilot goes out, wait 5 minutes and repeat

Steps 3-9.

1

1.

Release and turn knob counterclockwise to "ON".

12.

If appliance will not operate, follow the instructions "T

O TURN

OFF GAS T

O

APPLIANCE" and call your service technician or

gas supplier

.

NOTE: T

o

light main burner

, turn wall switch to "ON". Do not light by

hand.

T

O

TURN OFF GAS T

O

APPLIANCE

1.

T

u

rn of

f wall switch or set thermostat to lowest setting.

2.

Remove control access panel.

3.

T

u

rn manual gas valve to "CLOSED position. Do not force.

4.

Replace control access panel.

Due to high surface termperatures, keep children, clothing and furniture away

.

Keep burner and control compartment clean. See installation and operating instructions accompanying the appliance.

W

A

RNING:

If you do not follow these instructions exactly

, a fire or

explosion may result causing property damage, personal

injury or loss of life.

FOR YOUR SAFETY

READ BEFORE LIGHTING

29097D

This appliance needs fresh air for safe operation

and must be installed so there are provisions for

adequate combustion and ventilation air

.

This appliance must be installed in accordance with

local codes, if any; if not, follow ANSI Z223.1 or

, in

Canada, current CAN/CGA-B149.

W

A

RNING:

Improper installation,

adjustment, alteration, service or maintenance can

cause injury or property damage. Refer to the owner's

information manual provided with the appliance. For

assistance or additional information consult a

qualified installer

, service agency or the gas supplier

.

CAUTION:

Hot while in operation. Do not touch.

Keep children, clothing, furniture, gasoline and other liquids

having flammable vapors away

.

W

A

RNING RISK OF FIRE

This appliance is intended to burn a specified gas

fuel only

. Do not attempt to use with solid wood fuel

or another type of fuel. Do not attempt to modify or

use any other type of gas burner system.

*

Also certified for installation in a bedroom or a

bed-sitting room.

* For

U.S.

only!

C.

Use only your hand to push in or turn knob. Never use tools. If

the manual gas valve will not push in or turn by hand, don't try

to repair it; call a qualified service technician. Force or

attempted repair may result in a fire or explosion.

D.

Do not use this appliance if any part has been under water

.

Immediately call a qualified service technician to inspect the

appliance and to replace any part of the control system and any

gas control which has been under water

.

Stop! Read the safety information above on this label.

ON

OFF

PIL

OT

OFF PILOT

ON

OFF

PILOT

5

ON

OFF

VENT

ON

7

5

8

11

3. CLOSED

4. OPEN

W

A

RNING:

Disconnect the electric power

before servicing. If for any reason the original wire

supplied with the appliance must be replaced, it must be

replaced with 105° C or its equivalent.

For use with natural gas or propane. A

conversion

kit as supplied by the manufacturer shall be used to

convert this appliance to the alternative fuel.

This appliance must be properly connected to a

venting system in accordance with the

manufacturer's installation instructions.

NA

TURAL

GAS

Advertising