M-S Cash Drawer A794 User Manual

Page 128

Advertising
background image

A794 Owner’s Guide

Chapter 6: Programming Information

December 1999

123

Print Bar Code (continued)

Second Variation Length of Byte Specified at Beginning of String

The value of m selects the bar code system as described in the table. When details
present in the print buffer, the printer processes the data following m as normal data.

The variable d indicates the character code to be encoded into the specified bar code
system. See the table. If character code d cannot be encoded, the printer prints the bar
code data processed so far, and the following data is treated as normal data.

m

Bar Code

d

n, Length

65

UPC-A

48- 57 (ASCII numerals)

Fixed Length: 11, 12

66

UPC-E

48- 57

Fixed Length: 11, 12

67

JAN13 (EAN)

48- 57

Fixed Length: 12, 13

68

JAN8 (EAN)

48- 57

Fixed Length: 7, 8

69

CODE39

48- 57,
65- 90 (ASCII alphabet),
32, 36, 37, 43, 45, 46, 47 (ASCII special
characters)
d1 = dk = 42 (start/stop code is
supplied by printer if necessary)

Variable

70

Interleaved 2 of 5 (ITF)

48- 57

Variable (Even Number)

71

CODABAR (NW-7)

65- 68, start code
48- 57,
36, 43, 45, 46, 47, 58

Variable

72

Code 93

48- 57, 65- 90 (ASCII alphabet),
32, 36, 37, 43, 45, 46, 47 (ASCII special
characters)
d1 = dn = 42 (start/stop code is
supplied by printer if necessary)

Variable

73

Code 128*

0-105
d1 = 103-105 (must be a Start code)
d2 = 0-102 (data bytes)
(Stop code is provided by the printer)

Variable

75

PDF 417

0-255

Variable Length

Exceptions:

Code 93 and PDF 417 are only available in A794 Native Mode.

Select Bar Code Width

ASCII

GS w n

Hexadecimal

1D 77 n

Decimal

29 119 n

Value of n:

2, 3, 4, 5, 6

Default:

n=3

Sets the bar code width to n dots.

Formulas

n+1/8 mm (n+1/203 inch).

Advertising