User data storage commands – M-S Cash Drawer A794 User Manual

Page 137

Advertising
background image

Chapter 6: Programming Information

A794 Owner’s Guide

December 1999

132

User Data Storage Commands

Write to User Data Storage

ASCII

ESC ‘ m a0 a1 a2 d1 ... dm

Hexadecimal

1B 27 m a0 a1 a2 d1 ... dm

Decimal

27 39 m a0 a1 a2 d1 ... dm

Value of m:

0 – 255

Writes m bytes of data to the User Data Storage Flash Page at the address specified. The
printer waits for m bytes of data following the 3-byte address, addr.

If any of the memory locations addressed by this command are not currently erased, the
command is not executed.

Read from User Data Storage

ASCII

ESC 4 m a0 a1 a2

Hexadecimal

1B 34 m a0 a1 a2

Decimal

27 52 m a0 a1 a2

Value of m:

0 – 255

Reads m bytes of data from the User Data Storage Flash Page at the address specified.

Read from Non-Volatile Memory

ASCII

ESC j k

Hexadecimal

1B 6A k

Decimal

27 106 k

Range of k

:

20 – 63 (decimal)

Reads a two-byte word from location k in the history EEROM. The printer returns the
word at the next available opportunity.

Related Information:

This is ignored in TM-T88 Emulation and the parameter byte goes into the print buffer.

Write to Non-Volatile Memory (NVRAM)

ASCI

ESC s

n1 n2 k

Hexadecimal

1B 73

n1 n2 k

Decimal

27 115 n1 n2 k

Value of n1 :

1

st

Byte

Value of n2 :

2

nd

Byte

Range of k :

20 - 63 (decimal locations)

Writes the two-byte word, n1 n2, to location k in history EEROM.

Related Information:

This is ignored in TM-T88 Emulation and the parameter bytes go into the print buffer.