Serial Host Interface

SHI Clock Generator

MOTOROLA

DSP56012 User’s Manual

5-5

5.3

SHI CLOCK GENERATOR

The SHI clock generator generates the serial clock to the SHI if the interface operates
in the Master mode. The clock generator is disabled if the interface operates in the
Slave mode. When the SHI operates in the Slave mode, the clock is external and is
input to the SHI (HMST = 0).

Figure 5-2

illustrates the internal clock path

connections. It is the user’s responsibility to select the proper clock rate within the
range as defined in the I

2

C and SPI bus specifications.

5.4

SERIAL HOST INTERFACE PROGRAMMING MODEL

The Serial Host Interface programming model is divided in two parts:

Host side—see

Figure 5-3

below and

Section

5.4.1

on page 5-8

DSP side—see

Figure 5-4

on page 5-6 and

Sections

5.4.2

on page 5-8

through

5.4.6

on page 5-13 for detailed information

Figure 5-2 SHI Clock Generator

Figure 5-3 SHI Programming Model—Host Side

SHI

HMST

HMST = 0

HMST = 1

SCK/SCL

Divide By

1 or 8

Divide By 1

To

Divide By 64

HRS

HDM0–HDM5

SHI Clock

F

OSC

Divide

By 2

Controller

Clock

Logic

CPHA, CPOL, HI

2

C

AA0417k

0

I/O Shift Register (IOSR)

IOSR

23

AA0418

Advertising