2 rcs receiver 1 enable (r1en)—bit 1, 3 rcs reserved bit—bits 13 and 2, 4 rcs receiver master (rmst)—bit 3 – Motorola DSP56012 User Manual

Page 189: Table63 receiver word length control, Rcs receiver 1 enable (r1en)—bit 1 -11, Rcs reserved bit—bits 13 and 2 -11, Rcs receiver master (rmst)—bit 3 -11, Table 6-3, Receiver word length control -11

Advertising
background image

Serial Audio Interface

Serial Audio Interface Programming Model

MOTOROLA

DSP56012 User’s Manual

6-11

which is equivalent to the individual reset state. The R0EN bit is cleared during
hardware reset and software reset.

6.3.2.2

RCS Receiver 1 Enable (R1EN)—Bit 1

The read/write Receiver 1 Enable (R1EN) control bit enables the operation of SAI
Receiver 1. When R1EN is set, Receiver 1 is enabled. When R1EN is cleared, Receiver
1 is disabled. If both R0EN and R1EN are cleared, the receiver section is disabled,
which is equivalent to the individual reset state. The R1EN bit is cleared during
hardware reset and software reset.

6.3.2.3

RCS Reserved Bit—Bits 13 and 2

Bits 13 and 2 in the RCS are reserved and unused. They read as 0s and should be
written with 0s for future compatibility.

6.3.2.4

RCS Receiver Master (RMST)—Bit 3

The read/write control bit Receiver Master (RMST) switches the operation of the
receiver section between Master and Slave modes. When RMST is set, the SAI
receiver section is configured as a master. In the Master mode the receiver drives the
SCKR and WSR pins. When RMST is cleared, the SAI receiver section is configured as
a slave. In the Slave mode, the SCKR and WSR pins are driven from an external
source. The RMST bit is cleared during hardware reset and software reset.

6.3.2.5

RCS Receiver Word Length Control (RWL[1:0])—Bits 4 and 5

The read/write Receiver Word Length (RWL[1:0]) control bits are used to select the
length of the data words received by the SAI. The data word length is defined by the
number of serial clock cycles between two edges of the word select signal. Word
lengths of 16, 24, or 32 bits may be selected, as shown in Table 6-3.

The receive data registers are always loaded with 24 bits when a new data word
arrives. If the 16-bit word length is selected, the received 16-bit data word will be
placed in the 16 Most Significant Bits of the receive data register, independent of the
Receiver data shift Direction bit (RDIR, see below), while the 8 Least Significant Bits
of the receive data register are cleared. If a 32-bit word length is selected, 8 bits are

Table 6-3

Receiver Word Length Control

RWL1

RWL0

Number of Bits/Word

0

0

16

0

1

24

1

0

32

1

1

Reserved

Advertising