Part 3: prepare munchkin contender location, Continued), Notice – Munchkin Gas-Fired Hot Water Circulating Heater User Manual

Page 10: Warning

Advertising
background image

9

GAS-FIRED HEATER

Installation Manual

PART 3: PREPARE MUNCHKIN CONTENDER LOCATION

(CONTINUED)

BEFORE LOCATING THE MUNCHKIN
CONTENDER

1. Check for nearby connection to:

System water piping

Venting connections

Gas supply piping

Electrical power

2. Check area around heater. Remove any

combustible materials, gasoline and other
flammable liquids.

3. The Munchkin Contender must be installed

so that gas control system components are
protected from dripping or spraying water or
rain during operation or service.

4. If the new Munchkin Contender is to replace

an existing heater, check for and correct any
existing system problems such as:

System leaks.

Incorrectly-sized expansion tank.

Lack of freeze protection in heating water
causing system and heater to freeze and
leak.

Excessive glycol which will affect the
heater system operation.

C. CLEARANCES FOR SERVICE ACCESS

1. See Figure 3-1 for recommended service

clearances. If you do not provide minimum
clearances shown, it might not be possible to
service the heater without removing it from
the space.

WARNING

Failure to keep heater area clear and free of
combustible materials, gasoline and other
flammable liquids and vapors can result in
severe personal injury, death or substantial
property damage.

24"

FRONT CLEARANCE

24"

Figure 3-1: Clearances required

6"

6"

SIDE

CLEARANCE

SIDE

CLEARANCE

NOTICE

The Munchkin Contender Heater gas manifold
and controls met safe lighting and other
performance criteria when heater underwent
tests specified in ANSI Z21.10.3 — latest edition.

Advertising