2Unpacking to Installation

Setting the origin 2-13

2.3.2 Setting the origin with the origin data input method
(1) Confirming the origin data

The origin data to be input is noted in the
origin data sheet enclosed with the arm,
or on the origin data history table
attached to the back side of the shoulder
coverB. (Refer to

Fig. 2-8

).

Referring to

"5.3.2 Installing/removing

the cover" on page 44

, remove the

shoulder coverB, and confirm the value.

The value given in the default setting
column is the origin settings set with the
calibration jig before shipment.

Fig.2-8 : Origin data label (an example)

Always install/remove the cover with the controller control power turned OFF.
Failure to do so could lead to physical damage or personal injury should the robot
start moving due to incorrect operations.

(2) Turning ON the control power

Confirm that there are no operators near the robot before turning the power ON.

1) Turn the controller [POWER] switch ON.

The control power will be turned ON, and " □ . 100" will appear on the STATUS NUMBER display on the
front of the controller.

● Origin data history table (Origin Data History) Serial No.ES804008

(O: AlphabetO, 0: Zero)

Note) Meanings of symbols in method column
E: Jig method
N: Not used
SP: Not used

Date

Default

. . .

. . .

. . .

V!#S29

J 1

06DTYY

J 2

2?HL9X

J 3

1CP55V

J 4

T6!M$Y

J 5

Z2IJ%Z

J 6

A12%Z0

Method

E ・ N ・ S P

E ・ N ・
S P

E ・ N ・ S P