Installing the hand input cable

3Installing the option devices

3.2 Installing the hand input cable

The procedure for installing the hand input cable is as follows. Conduct work by referring to

"Fig. 3-1Solenoid

valve installation procedures" on page 31

and

"Fig. 3-4Installing the hand input cable" on page 34

below.

This work must be carried out with the controller power turned OFF.

Fig.3-4 : Installing the hand input cable

1) Remove the hexagon socket bolts (five M4 x 10) and truss screw (three M3 x 8) that hold the No. 2 arm cover

B <2>, and then remove both the No. 2 arm cover B <2>.

2) Remove the socket bolts <4> (four M4 x 8) that hold the No. 2 arm cover C <3> or the solenoid valves <5>,

and then remove the No. 2 arm cover C <3> or the solenoid valves <5>.

3) If you are not using the spare line (ADD: stored in a coil) in section A shown in

Fig. 3-1

, remove it. The spare

line is connected to a connector inside section A.

4) The hand input cable can be installed to both the No. 2 arm cover C <3> and the solenoid valves <5>.
5) Remove one of the two grommets on either the No. 2 arm cover C <3> or the solenoid valves <5>. After

removing the grommet, peal off the sealing material left on the hole section of the plate.

6) After removing the lock nut attached to the hand input cable, feed the connector side of the hand input cable

(with a cable clamp) through the hole on the plate. Replace the removed lock nut in position and fasten it
securely.

7) Connect the connectors of "HC1" and "HC2" stored in section A shown in

Fig. 3-1

to "HC1" and "HC2" of

the hand input cable.

8) Mount the No. 2 arm cover C <3> or the solenoid valves <5> to section A shown in

Fig. 3-1

. When mounting,

be careful not to damage the sponge sealing material attached to the opening of section A.

9) When you have completed the installation, reinstall the No.2 arm cover B <2> to its original position, and be

careful not to entangle the cables when you do so.

D

D

HC1

HC2

View D

<3> No. 2 arm cover C

Grommet

Remove

Lock nut

(M4×8, 4 bolts)

<4> Socket bolts

<5> Solenoid valves

Plate

Cable clamp

Remove

Grommet

Plate

Advertising