J3 axis, J6 axis j5 axis j4 axis, When an – MITSUBISHI ELECTRIC Mitsubishi Industrial Robot RV-6S User Manual

Page 32: Appears on the t/b screen display, J3 axis jog operation, J4, j5 and j6 axis jog

Advertising
background image

2-22

Confirming the operation

2Unpacking to Installation

・ When the [MOVE] + [+Z (J3)] keys are pressed, the J3 axis will rotate in the plus direction.

When the [MOVE] + [-Z (J3)] keys are pressed, Rotate in the minus direction.

・ When the [MOVE] + [+A (J4)] keys are pressed, the J4 axis will rotate in the plus direction.

When the [MOVE] + [-A (J4)] keys are pressed, Rotate in the minus direction.

・ When the [MOVE] + [+B (J5)] keys are pressed, the J5 axis will rotate in the plus direction

When the [MOVE] + [-B (J5)] keys are pressed, Rotate in the minus direction.

・ When the [MOVE] + [+C (J6)] keys are pressed, the J6 axis will rotate in the plus direction

When the [MOVE] + [-C (J6)] keys are pressed, Rotate in the minus direction.

STEP

MOVE

3

    JKL

- Z

(J3)

STEP

MOVE

8

    , @\

+ Z

(J3)

J3 axis

J3 axis jog operation

STEP

MOVE

6

  

VWX

+ B

(J5)

STEP

MOVE

0

  

ABC

- C

(J6)

5

  

STU

+ C

(J6)

STEP

MOVE

1

  

DEF

- B

(J5)

STEP

MOVE

7

  

YZ_

+ A

(J4)

STEP

MOVE

J6 axis

J5 axis

J4 axis

  

2

GHI

- A

(J4)

STEP

MOVE

J4, J5 and J6 axis jog

◇◆◇ When an

X

appears on the T/B screen display ◇◆◇

If the robot is moved outside the movement area, an X will appear. In this case, move the axis in the opposite
direction.

In the example on the left, the J1 axis is at the limit of the plus side movement area.

JOINT LOW
X J1 +160.00
J2 +20.00
J3 +80.00

Advertising