6) j6 axis origin setting, 6) j6 axis origin setting -60, Caution – MITSUBISHI ELECTRIC Mitsubishi Industrial Robot RV-6S User Manual

Page 70

Advertising
background image

5-60

Resetting the origin

5Maintenance and Inspection

(6) J6 axis origin setting

1) Slowly move the J6 axis with both hands, and

align the ABS mark of the wrist housing with the
ABS mark of the hand mounting flange.

2) Press the [ ↓ ] key. The cursor will move to

"SET AXIS".

3) Designate the axis for which the origin is to be

set.. Set "1" for the 6 axis, and set "0" for the
other axes. Then, press [INP] key. Next, a
confirmation screen will appear.

4) Press the [1] and [INP] keys.

The origin posture will be set.

5) Setting of the origin is completed.

6) Refer to

"5.5.4Recording the origin data" on

page 65

in this manual, and record the origin data

on the origin data seal.

This completes the setting of the origin with the jig method.

Designate the origin setting axis

-B

(J5)

1

DEF

-C

(J6)

0

ABC

INP

EXE

Set the origin

-B

(J5)

1

DEF

INP

EXE

Designate the origin setting axis

-B

(J5)

1

DEF

Move the cursor

RPL

<TOOL> 12345678
BRAKE

(00000000)

SET AXIS(11110000)
ORIGIN :NOT DEF

<TOOL> 12345678
BRAKE

(00000000)

SET AXIS (00000100)
ORIGIN :NOT DEF

<TOOL>
SET ORIGIN
OK?(1)
1:EXECUTE

<TOOL> 12345678
BRAKE

(00000000)

SET AXIS (

00000

100)

ORIGIN :COMPLETED

The J6-axis dose not have
a mechanical stopper.
When setting the origin
position , do not rotate the
axis more than themotion
range( ± 200 deg.).  

CAUTION

Bolt (M5: 2 bolts)

J6 axis

ABS mark

Prepared by customer

◇◆◇ Origin setting axis designation ◇◆◇

Move the cursor to the "SET AXIS" axis No. in the origin setting with the [ ← ] or [ → ] key.
The origin is set only for the axis for which a "1" is displayed on the screen. If the origin is not to be set, press
the [0] key and display a "0".