Li.rfpcb0, Li.rfpcb1, Li.rfpcb2 – Maxim Integrated DS33R11 User Manual

Page 166

Advertising
background image

DS33R11 Ethernet Mapper with Integrated T1/E1/J1 Transceiver

166 of 344


Register Name:

LI.RFPCB0

Register Description:

Receive FCS Errored Packet Count Byte 0 Register

Register Address:

10Ch


Bit

# 7 6 5 4 3 2 1 0

Name

RFPC7

RFPC6

RFPC5

RFPC4

RFPC3

RFPC2

RFPC1

RFPC0

Default

0 0 0 0 0 0 0 0


Bits 0 – 7: Receive FCS Errored Packet Count (RFPC[7:0]) Eight bits of a 24-bit value. Register description
below.

Register Name:

LI.RFPCB1

Register Description:

Receive FCS Errored Packet Count Byte 1 Register

Register Address:

10Dh


Bit

# 7 6 5 4 3 2 1 0

Name

RFPC15

RFPC14

RFPC13

RFPC12

RFPC11

RFPC10

RFPC9

RFPC8

Default

0 0 0 0 0 0 0 0


Bits 0 – 7: Receive FCS Errored Packet Count (RFPC[15:8])
Eight bits of a 24-bit value. Register description
below.


Register Name:

LI.RFPCB2

Register Description:

Receive FCS Errored Packet Count Byte 2 Register

Register Address:

10Eh


Bit

# 7 6 5 4 3 2 1 0

Name

RFPC23

RFPC22

RFPC21

RFPC20

RFPC19

RFPC18

RFPC17

RFPC16

Default

0 0 0 0 0 0 0 0

Receive FCS Errored Packet Count (RFPC[23:16]) These twenty-four bits indicate the number of packets
received with an FCS error. The byte count for these packets is included in the receive aborted byte count register
REBCR.

Advertising