DS33R11 Ethernet Mapper with Integrated T1/E1/J1 Transceiver

291 of 344

Register Name:

TR.BRP1

Register Description:

BERT Repetitive Pattern Set Register 1

Register Address:

DCh


Bit

# 7 6 5 4 3 2 1 0

Name RPAT7 RPAT6 RPAT5 RPAT4 RPAT3 RPAT2 RPAT1 RPAT0
Default

0 0 0 0 0 0 0 0


Bits 0 – 7: BERT Repetitive Pattern Set Bits 0 to 7 (RPAT0 to RPAT7)
RPAT0 is the LSB of the 32-bit repetitive
pattern set.


Register Name:

TR.BRP2

Register Description:

BERT Repetitive Pattern Set Register 2

Register Address:

DDh


Bit

# 7 6 5 4 3 2 1 0

Name RPAT15

RPAT14

RPAT13

RPAT12 RPAT11 RPAT10 RPAT9 RPAT8

Default

0 0 0 0 0 0 0 0


Bits 0 – 7: BERT Repetitive Pattern Set Bits 8 to 15 (RPAT8 to RPAT15)


Register Name:

TR.BRP3

Register Description:

BERT Repetitive Pattern Set Register 3

Register Address:

DEh


Bit

# 7 6 5 4 3 2 1 0

Name RPAT23

RPAT22

RPAT21

RPAT20 RPAT19 RPAT18 RPAT17 RPAT16

Default

0 0 0 0 0 0 0 0


Bits 0 – 7: BERT Repetitive Pattern Set Bits 16 to 23 (RPAT16 to RPAT23)


Register Name:

TR.BRP4

Register Description:

BERT Repetitive Pattern Set Register 4

Register Address:

DFh


Bit

# 7 6 5 4 3 2 1 0

Name RPAT31

RPAT30

RPAT29

RPAT28 RPAT27 RPAT26 RPAT25 RPAT24

Default

0 0 0 0 0 0 0 0


Bits 0 – 7: BERT Repetitive Pattern Set Bits 24 to 31 (RPAT24 to RPAT31). RPAT31 is the LSB of the 32-bit
repetitive pattern set.