Maxim Integrated DS33R11 User Manual

Page 225

Advertising
background image

DS33R11 Ethernet Mapper with Integrated T1/E1/J1 Transceiver

225 of 344

Register Name:

TR.SR6, TR.SR7

Register Description:

HDLC #1 Status Register 6
HDLC #2 Status Register 7

Register Address:

20h, 22h


Bit

# 7 6 5 4 3 2 1 0

Name —

TMEND

RPE RPS

RHWM

RNE

TLWM

TNF

Default

0 0 0 0 0 0 0 0


Bit 6: Transmit Message-End Event (TMEND).
Set when the transmit HDLC controller has finished sending a
message. This is a latched bit and is cleared when read.

Bit 5: Receive Packet-End Event (RPE).
Set when the HDLC controller detects either the finish of a valid
message (i.e., CRC check complete) or when the controller has experienced a message fault such as a CRC
checking error, or an overrun condition, or an abort has been seen. This is a latched bit and is cleared when read.

Bit 4: Receive Packet-Start Event (RPS)
. Set when the HDLC controller detects an opening byte. This is a
latched bit and is cleared when read.

Bit 3: Receive FIFO Above High-Watermark Condition (RHWM).
Set when the receive 128-byte FIFO fills
beyond the high watermark as defined by the receive high-watermark register (TR.RHWMR).

Bit 2: Receive FIFO Not Empty Condition (RNE).
Set when the receive 128-byte FIFO has at least 1 byte
available for a read.

Bit 1: Transmit FIFO Below Low-Watermark Condition (TLWM). Set when the transmit 128-byte FIFO empties
beyond the low watermark as defined by the transmit low-watermark register (TR.TLWMR).

Bit 0: Transmit FIFO Not Full Condition (TNF). Set when the transmit 128-byte FIFO has at least 1 byte
available.