Register Name:

TR.E1TCR2

Register Description:

E1 Transmit Control Register 2

Register Address:

36h


Bit

# 7 6 5 4 3 2 1 0

Name

- - - - -

AEBE

AAIS

ARA

Default

0 0 0 0 0 0 0 0


Bit 2: Automatic E-Bit Enable (AEBE)

0 = E-bits not automatically set in the transmit direction
1 = E-bits automatically set in the transmit direction


Bit 1: Automatic AIS Generation (AAIS)

0 = disabled
1 = enabled


Bit 0: Automatic Remote Alarm Generation (ARA)

0 = disabled
1 = enabled


Register Name:

TR.BOCC

Register Description:

BOC Control Register

Register Address:

37h


Bit

# 7 6 5 4 3 2 1 0

Name — — —

RBOCE

RBR

RBF1

RBF0

SBOC

Default

0 0 0 0 0 0 0 0


Bit 4: Receive BOC Enable (RBOCE). Enables the receive BOC function. The TR.RFDL register reports the
received BOC code and two information bits when this bit is set.

0 = receive BOC function disabled
1 = receive BOC function enabled; the TR.RFDL register reports BOC messages and information


Bit 3: Receive BOC Reset (RBR).
A 0-to-1 transition resets the BOC circuitry. Must be cleared and set again for a
subsequent reset.

Bits 1 – 2: Receive BOC Filter Bits (RBF0, RBF1). The BOC filter sets the number of consecutive patterns that
must be received without error prior to an indication of a valid message.

RBF1 RBF0

Consecutive BOC Codes for

Valid Sequence Identification

0 0

None

0 1

3

1 0

5

1 1

7


Bit 0: Send BOC (SBOC). Set = 1 to transmit the BOC code placed in bits 0 to 5 of the TR.TFDL register.