DS33R11 Ethernet Mapper with Integrated T1/E1/J1 Transceiver

274 of 344


Register Name:

TR.RUPCD1

Register Description:

Receive Up-Code Definition Register 1

Register Address:

B9h


Bit

# 7 6 5 4 3 2 1 0

Name

C7 C6 C5 C4 C3 C2 C1 C0

Default

0 0 0 0 0 0 0 0

Note: Writing this register resets the detector’s integration period.

Bit 7: Receive Up-Code Definition Bit 7 (C7).
First bit of the repeating pattern.

Bit 6: Receive Up-Code Definition Bit 6 (C6).
A don’t care if a 1-bit length is selected.

Bit 5: Receive Up-Code Definition Bit 5 (C5).
A don’t care if a 1-bit or 2-bit length is selected.

Bit 4: Receive Up-Code Definition Bit 4 (C4).
A don’t care if a 1-bit to 3-bit length is selected.

Bit 3: Receive Up-Code Definition Bit 3 (C3).
A don’t care if a 1-bit to 4-bit length is selected.

Bit 2: Receive Up-Code Definition Bit 2 (C2).
A don’t care if a 1-bit to 5-bit length is selected.

Bit 1: Receive Up-Code Definition Bit 1 (C1). A don’t care if a 1-bit to 6-bit length is selected.

Bit 0: Receive Up-Code Definition Bit 0 (C0). A don’t care if a 1-bit to 7-bit length is selected.


Register Name:

TR.RUPCD2

Register Description:

Receive Up-Code Definition Register 2

Register Address:

BAh


Bit

# 7 6 5 4 3 2 1 0

Name

C7 C6 C5 C4 C3 C2 C1 C0

Default

0 0 0 0 0 0 0 0


Bits 0 – 7: Receive Up-Code Definition Bits 0–7 (C0–C7). A don’t care if a 1-bit to 7-bit length is selected.