DS33R11 Ethernet Mapper with Integrated T1/E1/J1 Transceiver

219 of 344


Register Name:

TR.SR3

Register Description:

Status Register 3

Register Address:

1Ah


Bit

# 7 6 5 4 3 2 1 0

Name LSPARE LDN

LUP LOTC LORC V52LNK RDMA RRA

Default

0 0 0 0 0 0 0 0


Bit 7: Spare Code Detected Condition (LSPARE) (T1 Only).
Set when the spare code as defined in the
TR.RSCD1/2 registers is being received. See Section

10.19

for details. This is a double interrupt bit. See Section

9.7

.


Bit 6: Loop-Down Code Detected Condition (LDN) (T1 Only). Set when the loop down code as defined in the
TR.RDNCD1/2 register is being received. See Section

10.19

for details. This is a double interrupt bit. See Section

9.7

.


Bit 5: Loop-Up Code Detected Condition (LUP)
(T1 Only). Set when the loop-up code as defined in the
TR.RUPCD1/2 register is being received. See Section

10.19

for details. This is a double interrupt bit. See Section

9.7

.


Bit 4: Loss-of-Transmit Clock Condition (LOTC). Set when the TCLKT pin has not transitioned for one channel
time. Forces the LOTC pin high if enabled by TR.CCR1.0. This is a double interrupt bit. See Section

9.7

.


Bit 3: Loss-of-Receive Clock Condition (LORC). Set when the RDCLKI pin has not transitioned for one channel
time. This is a double interrupt bit. See Section

9.7

.


Bit 2: V5.2 Link Detected Condition (V52LNK) (E1 Only). Set on detection of a V5.2 link identification signal
(G.965). This is a double interrupt bit. See Section

9.7

.


Bit 1: Receive Distant MF Alarm Condition (RDMA) (E1 Only).
Set when bit 6 of time slot 16 in frame 0 has
been set for two consecutive multiframes. This alarm is not disabled in the CCS signaling mode. This is a double
interrupt bit. See Section

9.7

.


Bit 0: Receive Remote Alarm Condition (RRA) (E1 Only). Set when a remote alarm is received at RPOSI and
RNEGI. This is a double interrupt bit. See Section

9.7

.