DS33R11 Ethernet Mapper with Integrated T1/E1/J1 Transceiver

217 of 344

Register Name:

TR.SR2

Register Description:

Status Register 2

Register Address:

18h


Bit

# 7 6 5 4 3 2 1 0

Name RYELC RUA1C FRCLC

RLOSC RYEL RUA1 FRCL RLOS

Default

0 0 0 0 0 0 0 0


Bit 7: Receive Yellow Alarm Clear Event (RYELC)
(T1 Only). Set when the receive Yellow Alarm condition is no
longer detected.

Bit 6: Receive Unframed All-Ones Clear Event (RUA1C). Set when the unframed all 1s condition is no longer
detected.

Bit 5: Framer Receive Carrier-Loss Clear Event (FRCLC).
Set when the carrier loss condition at RPOSI and
RNEGI is no longer detected.

Bit 4: Receive Loss-of-Sync Clear Event (RLOSC).
Set when the framer achieves synchronization; remains set
until read.

Bit 3: Receive Yellow Alarm Condition (RYEL) (T1 Only). Set when a Yellow Alarm is received at RPOSI and
RNEGI.

Bit 2: Receive Unframed All-Ones (T1 Blue Alarm, E1 AIS) Condition (RUA1). Set when an unframed all 1s
code is received at RPOSI and RNEGI.

Bit 1: Framer Receive Carrier-Loss Condition (FRCL). Set when 255 (or 2048 if TR.E1RCR2.0 = 1) E1 mode or
192 T1 mode consecutive 0s have been detected at RPOSI and RNEGI.

Bit 0: Receive Loss-of-Sync Condition (RLOS). Set when the transceiver is not synchronized to the received
data stream.