1 start condition, 2 no start or stop condition, 3 stop condition – Intel CONTROLLERS 413808 User Manual

Page 696: Figure 94. start and stop conditions, 94 start and stop conditions, Section 14.2.3.1, “start condition” on, The start condition (bits 1:0 of the icr set to 01, Cbus when the icr transfer byte bit is set. the i, C unit functions under those circumstances, C unit holds the

Advertising
background image

Intel

®

413808 and 413812—I

2

C Bus Interface Units

Intel

®

413808 and 413812 I/O Controllers in TPER Mode

Developer’s Manual

October 2007

696

Order Number: 317805-001US

14.2.3.1

START Condition

The START condition (bits 1:0 of the ICR set to 01

2

) initiates a master transaction or

repeated START. Software must load the

target slave address and the R/W# bit in the

IDBR (see

Section 14.8.4, “I2C Data Buffer Register x — IDBRx” on page 720

) before

setting the START ICR bit. The START and the IDBR contents are transmitted on the I

2

C

bus when the ICR Transfer Byte bit is set. The I

2

C bus stays in master-transmit mode

when a write is requested or enters master-receive mode when a read is requested. For

a repeated start (a change in read or write or a change in the target slave address), the

IDBR contains the updated target slave address and the R/W# bit. A repeated start

enables multiple transfers to different slaves without giving up the bus.
The START condition is not cleared by the I

2

C unit. When arbitration is lost while

initiating a START, the I

2

C unit may re-attempt the START when the bus becomes free.

See

Section 14.3.3, “Arbitration” on page 700

for details on how the I

2

C unit functions

under those circumstances.

14.2.3.2

No START or STOP Condition

No START or STOP condition (bits 1:0 of the ICR set to 00

2

) is used in master-transmit

mode while the 4138xx is transmitting multiple data bytes (see

Figure 93

). Software

writes the data byte, sets the IDBR Transmit Empty bit in the ISR (and interrupt when

enabled), and clears the Transfer Byte bit in the ICR. The software then writes a new

byte to the IDBR and sets the Transfer Byte ICR bit, which initiates the new byte

transmission. This continues until the software sets the START or STOP bit. The START

and STOP bits in the ICR are not automatically cleared by the I

2

C unit after the

transmission of a START, STOP or repeated START.
After each byte transfer (including the Ack/Nack bit) the I

2

C unit holds the

SCL

line low

(inserting wait states) until the Transfer Byte bit in the ICR is set. This action notifies

the I

2

C unit to release the

SCL

line and allow the next information transfer to proceed.

14.2.3.3

STOP Condition

The STOP condition (bits 1:0 of the ICR set to 10

2

) terminates a data transfer. In

master-transmit mode, the STOP bit and the Transfer Byte bit in the ICR must be set to

initiate the last byte transfer (see

Figure 93

). In master-receive mode, to initiate the

last transfer the 4138xx must set the Ack/Nack bit, the STOP bit, and the Transfer Byte

bit in the ICR. Software must clear the STOP condition after it is transmitted.

Figure 94. START and STOP Conditions

Data byte

Ack/

Nack

R/W#

START Target Slave Address

R/W#

Data Byte

STOP

No START or STOP Condition

START Condition

STOP Condition

Ack/

Nack

Ack/

Nack

B6284-01