Janome MEMORY CRAFT 10001 User Manual

Page 19

Advertising
background image

18

1

2

3

4

Changing Needles

Raise the needle by pressing the Up/Down
Needle Button and lower the Presser Foot.
Turn off the Power Switch.

Loosen the Needle Clamp Screw by turning
it counterclockwise.

Remove the Needle from the Needle
Clamp.

1

Needle Clamp Screw

2

Needle

3

Needle Clamp

Insert a new needle into the Needle Clamp
with the Flat Side of the Needle to the rear.

When inserting the Needle into the Needle
Clamp, push it up as far as it will go and
tighten the Needle Clamp Screw firmly.

4

Flat Side of the Needle

To check needle straightness, place the flat
side of the needle onto something flat (a
needle plate, glass etc.) The gap between
the needle and the flat surface should be
consistent.
Never use a blunt needle.

3