Supply voltage, Power consumption, Reset timing – Kane Industries C6713CPU User Manual

Page 49: Ambient temperature, Ambient humidity, Table 18: voltage limits for the c6713cpu, Table 19: power consumption of the c6713cpu, Table 20: reset timing, Caution

Advertising
background image

H

ARDWARE

R

EFERENCE

G

UIDE

MICRO

-

LINE

®

C6713CPU

Date : 28 November 2005
Doc. no. : C6713CPU_HRG
Iss./Rev : 1.1
Page : 49

7.4 Supply

Voltage

The C6713CPU must be supplied with a voltage of nominal +3.3 V. The integrated switching
voltage regulators generate all necessary on-board voltages.

CAUTION:

The C6713CPU is not protected against reversed voltage. Please be careful when connecting
power supply to the board. Applying reversed voltage will damage the board.

CAUTION:

The power up voltage ramp time must be at least 0.6 ms. The ramp time is measured from 10% to
90% of the full nominal voltage swing. Direct plugging a 3.3V power cable into a working 3.3V
power supply may damage the board.

Board type

minimum allowed supply voltage maximum allowed supply voltage

C6713CPU

3.25 V

3.35 V

Table 18: Voltage limits for the C6713CPU

7.5 Power

Consumption

The typical power consumption is shown in the following table. Please note that the power
consumption strongly depends on I/O pin usage and the FPGA design.

Condition

Typical power consumption

Toggle_led_1 example, any board, FPGA loaded

460 mA

Toggle_led_fpga example, any board, FPGA loaded

470 mA

Table 19: Power consumption of the C6713CPU

7.6 Reset

Timing

Parameter

Min

Typ

Max

/RESETIN pulse width

1

µs

(/)RESETOUT pulse width

140ms

200ms

280ms

Watchdog timeout

1.6s

Table 20: Reset timing

7.7 Ambient

Temperature

Storage temperature:

-25..+85° C

Operating temperature: 0..+70° C
Extended temperature versions are available on request

7.8 Ambient

Humidity

Storage with up to 90% humidity, non condensing
Operating with up to 85% humidity, non condensing

Advertising