Symptoms, Major physical or electrical damage is evident, Machine is dead - no output, no fan, no display – Lincoln Electric IDEALARC CV-305 User Manual

Page 36: Troubleshooting & repair, Caution

Advertising
background image

OUTPUT PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,

contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.

Call 1-888-935-3877.

CAUTION

Major

Physical

or

Electrical

Damage is Evident

1.

Contact

your

local

Lincoln

Electric Authorized Field Service

Facility.

1.

Contact The Lincoln Electric

Service Dept. 1-888-935-3877

Machine is dead - No output, no fan,

no display.

1.

Check

for

blown

or

missing

fuses in the input line.

2.

Check the three phase input line

voltage at the machine.

Input

voltage must match the rating

plate and the reconnect panel.

1.

Check input line switch may be

faulty. Check or replace.

2.

Remove the input power and

check for loose or broken leads

at the reconnect panel and at

the main transformer primary

coils.

3.

Perform

Main Transformer

Test.

The machine has no output. The

fan runs and the display lights.

1.

Make sure the thermal light is

NOT lit (earlier codes the pilot

light is NOT blinking).

If either

condition

exists,

then

the

machine may be overheated.

2.

If an error message is displayed,

see

Explanation of Error

Messages.

3.

Make sure the three phase input

voltage matches the reconnect

panel configuration and that all

three phases are applied to the

machine.

4.

Place a jumper wire from pin “C”

to pin “D” at the 14 pin amphenol

connection. If output is restored,

then check the wirefeeder and

associated control cable.

1.

Check the trigger circuit (#2 and

#4) for continuity from the 14 pin

amphenol to the control board.

See wiring diagram.

2.

If the machine has output in

machine

control

but

not

in

remote

control,

check

the

remote switch (S4).

Check the

wiring to the control board and to

the 14 pin amphenol.

3.

Swap any two of the three phase

input. If output returns, the Line

Switch is faulty.

4.

Check for loose or faulty con-

nections at the output terminals

and the heavy current carrying

leads.

5.

The control board may be faulty.

Replace.

TROUBLESHOOTING & REPAIR

F-4

F-4

IDEALARC® CV-305

Re

tu

rn

to

Se

ct

io

n

T

O

C

Re

tu

rn

to

Se

ct

io

n

T

O

C

Re

tu

rn

to

Se

ct

io

n

T

O

C

Re

tu

rn

to

Se

ct

io

n

T

O

C

Re

tu

rn

to

M

a

st

e

r

T

O

C

Re

tu

rn

to

M

a

st

e

r

T

O

C

Re

tu

rn

to

M

a

st

e

r

T

O

C

Re

tu

rn

to

M

a

st

e

r

T

O

C

Advertising