Troubleshooting & repair – Lincoln Electric IDEALARC CV-305 User Manual

Page 63

Advertising
background image

TROUBLESHOOTING & REPAIR

F-31

F-31

IDEALARC® CV-305

5ms

20V

0 Volts

CH1

This is not a typical CV output voltage wave-

form.

Note the “ripple” in the waveform.

One output SCR was disconnected to simu-

late an open or non-functioning output SCR.

Note that each vertical division represents

20 volts and each horizontal division repre-

sents 5 milliseconds in time.

Note: Scope probes connected at machine

high inductance output terminals.

Volts/Div . . . . . . . . . . . . . . . . . .20 V/Div.

Horizontal Sweep

. . . . . . . . . .5 ms/Div.

Coupling . . . . . . . . . . . . . . . . . . . . . .DC.

Trigger

. . . . . . . . . . . . . . . . . . . .Internal.

SCOPE SETTINGS

MACHINE LOADED TO 300 AMPS AT 32 VDC

ABNORMAL OUTPUT WELD VOLTAGE WAVEFORM -

MACHINE LOADED ONE OUTPUT SCR NOT FUNCTIONING