Troubleshooting & repair – Lincoln Electric IDEALARC CV-305 User Manual

Page 52

Advertising
background image

STATIC OUTPUT RECTIFIER BRIDGE TEST PROCEDURE

(CONTINUED)

TROUBLESHOOTING & REPAIR

F-20

F-20

IDEALARC® CV-305

10. Test diode D1 for proper operation.

a.

Measure the resistance of diode D1 from the

anode (+ probe) to the cathode (- probe) using

an analog volt-ohm meter (Multimeter) set at R

X 1000 scale. Resistance should be low. See

Figure F.7.

b.

Reverse the meter leads and measure the

resistance from the cathode (+ probe) to anode

(- probe) of D1.

Resistance should be High.

See Figure F.7.

c.

If the resistance is low for both tests a and b,

the diode is shorted. Replace.

d.

If the resistance is high for both test a and b, the

diode is open. Replace.

11. Test Diodes D2, D3, D4 & D5 for proper operation

using the same procedure described in Step 10.

NOTE: Diodes D1, D2 & D3 do not need to be discon-

nected for this test.

12. Reconnect all leads and Molex plugs disconnected

for this test.

13. If these tests did not identify the problem or to fur-

ther test the SCR’s, go to the

Active SCR Test.

D1

D4

D2

Capacitor

Bank

D5

Copper

Strap

D3

Positive

Heat Sink

Power Factor

Choke Lead

*

*

*

*

The Bus Bar where the D1, D2 and D3 pigtails are normally connected is not shown for clarity.

Positive lead

to Shunt

FIGURE F.7 - RECTIFIER/CAPACITOR ASSEMBLY

Re

tu

rn

to

Se

ct

io

n

T

O

C

Re

tu

rn

to

Se

ct

io

n

T

O

C

Re

tu

rn

to

Se

ct

io

n

T

O

C

Re

tu

rn

to

Se

ct

io

n

T

O

C

Re

tu

rn

to

M

a

st

e

r

T

O

C

Re

tu

rn

to

M

a

st

e

r

T

O

C

Re

tu

rn

to

M

a

st

e

r

T

O

C

Re

tu

rn

to

M

a

st

e

r

T

O

C

Advertising