RETEST AFTER REPAIR
TROUBLESHOOTING & REPAIR
F-55
F-55
IDEALARC® CV-305
Maximum Idle Watts
950 watts
950 watts
950 watts
950 watts
INPUT IDLE AMPS AND WATTS
Should a machine require the removal of any mechanical part that could affect the machine’s electrical character-
istics, or if any electrical components are repaired or replaced, that machine must be retested.
OUTPUT LOAD READINGS
OPEN CIRCUIT VOLTAGE
Maximum Idle Amps
Input Volts/Hertz
8
7
3.4
3
208/3/60
230/3/60
460/3/60
575/3/60
Volts
1-7 VDC
36 VDC Minimum
Amps
Output Control Setting
40-50
410
Minimum
Maximum
Mode
Open Circuit Volts
Maximum
Normal Range
Auxiliary Output (#31 - #32)
Auxiliary Output (#41 - #42 (#32A))
55 VDC
10-43 VDC
112/119 VAC
39/42 VAC