TROUBLESHOOTING & REPAIR
F-30
F-30
IDEALARC® CV-305
5ms
20V
0 Volts
CH1
This is a typical CV output voltage generat-
ed from a properly operating machine. Note
that each vertical division represents 20
volts and that each horizontal division repre-
sents 5 milliseconds in time.
The machine was loaded with a resistance
grid bank.
Note: Scope probes connected at machine
high inductance output terminals.
Volts/Div . . . . . . . . . . . . . . . . . .20 V/Div.
Horizontal Sweep
. . . . . . . . . .5 ms/Div.
Coupling . . . . . . . . . . . . . . . . . . . . . .DC.
Trigger
. . . . . . . . . . . . . . . . . . . .Internal.
SCOPE SETTINGS
MACHINE LOADED TO 300 AMPS AT 32 VDC