FUNCTION PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
The machine will NOT shut off.
1.
Make sure the three phase input
lines
are
connected
to
the
machine correctly.
2.
Contact
your
local
Lincoln
Authorized
Field
Service
Facility.
1.
The input line switch may be
faulty. Replace.
The output voltage cannot be pre-
set.
1.
Place
the
remote
switch
in
machine control. If normal oper-
ation is restored then the remote
control
unit
may
be
faulty.
Check or replace.
2.
If an error message is displayed
see
1.
Check the output control (R2)
and associated circuitry.
2.
The meter board may be faulty.
Replace.
3.
The control board may be faulty.
Replace.