Troubleshooting & repair – Lincoln Electric IDEALARC CV-305 User Manual
Page 64
TROUBLESHOOTING & REPAIR
F-32
F-32
IDEALARC® CV-305
5ms
20V
0 Volts
CH1
This is NOT the typical output voltage wave-
form. Note the increased “ripple” in the out-
put waveform. The output capacitors were
disconnected to simulate a faulty capacitor
bank. Note that each vertical division repre-
sents 20 volts and each horizontal division
represents 5 milliseconds in time.
Note: Scope probes connected at machine
high inductance output terminals.
Volts/Div . . . . . . . . . . . . . . . . . .20 V/Div.
Horizontal Sweep
. . . . . . . . . .5 ms/Div.
Coupling . . . . . . . . . . . . . . . . . . . . . .DC.
Trigger
. . . . . . . . . . . . . . . . . . . .Internal.
SCOPE SETTINGS
MACHINE LOADED TO 300 AMPS AT 15 VDC
ABNORMAL OUTPUT WELD VOLTAGE WAVEFORM - MACHINE LOADED
CAPACITOR BANK NOT FUNCTIONING