TROUBLESHOOTING & REPAIR

F-32

F-32

IDEALARC® CV-305

5ms

20V

0 Volts

CH1

This is NOT the typical output voltage wave-

form. Note the increased “ripple” in the out-

put waveform. The output capacitors were

disconnected to simulate a faulty capacitor

bank. Note that each vertical division repre-

sents 20 volts and each horizontal division

represents 5 milliseconds in time.

Note: Scope probes connected at machine

high inductance output terminals.

Volts/Div . . . . . . . . . . . . . . . . . .20 V/Div.

Horizontal Sweep

. . . . . . . . . .5 ms/Div.

Coupling . . . . . . . . . . . . . . . . . . . . . .DC.

Trigger

. . . . . . . . . . . . . . . . . . . .Internal.

SCOPE SETTINGS

MACHINE LOADED TO 300 AMPS AT 15 VDC

ABNORMAL OUTPUT WELD VOLTAGE WAVEFORM - MACHINE LOADED

CAPACITOR BANK NOT FUNCTIONING