Troubleshooting & repair – Lincoln Electric IDEALARC CV-305 User Manual

Page 65

Advertising
background image

TROUBLESHOOTING & REPAIR

F-33

F-33

IDEALARC® CV-305

5ms

20V

0 Volts

CH1

This is not the typical output voltage wave-

form.

The output capacitors were discon-

nected to simulate a faulty capacitor bank.

Note the absence of “filtering” in the wave-

form. Note that each vertical division repre-

sents 20 volts and each horizontal division

represents 5 milliseconds in time.

Note: Scope probes connected at machine

high inductance output terminals.

Volts/Div . . . . . . . . . . . . . . . . . .20 V/Div.

Horizontal Sweep

. . . . . . . . . .5 ms/Div.

Coupling . . . . . . . . . . . . . . . . . . . . . .DC.

Trigger

. . . . . . . . . . . . . . . . . . . .Internal.

SCOPE SETTINGS

ABNORMAL OPEN CIRCUIT WELD VOLTAGE WAVEFORM

NO LOAD - CAPACITOR BANK NOT FUNCTIONING