Location, Installation, Safety precautions select suitable location – Lincoln Electric IDEALARC CV-305 User Manual

Page 9: Input connections, Warning, Caution, Stacking, Tilting, Recommended input wire and fuse sizes

Advertising
background image

INSTALLATION

A-3

A-3

IDEALARC® CV-305

Read entire installation section before starting

installation.

SAFETY PRECAUTIONS

SELECT SUITABLE LOCATION

Place the welder where clean cooling air can freely

circulate in through the side louvers and out through

the rear louvers. Dirt, dust or any foreign material that

can be drawn into the welder should be kept at a

minimum. Failure to observe these precautions can

result

in

excessive

operating

temperatures

and

nuisance shut-downs. Idealarc CV-305 power sources

carry an IP21S enclosure rating. They are rated for use

in damp, dirty environments subject to occasional

falling water such as rain.

DO NOT MOUNT OVER COMBUSTIBLE SUR-

FACES.

Where there is a combustible surface directly under

stationary or fixed electrical equipment, the surface

shall be covered with a steel plate at least .06”(1.6mm)

thick, which shall extend not more than 5.90”(150mm)

beyond the equipment on all sides.

------------------------------------------------------------------------

STACKING

The CV-305 may be stacked three-high provided the

bottom machine is on a stable, hard, level surface. Be

sure that the two pins in the roof fit into the slots in the

base of the CV-305 above it.

TILTING

Do not place the machine on a surface that is inclined

enough to create a risk of the machine falling over.

INPUT CONNECTIONS

Be sure the voltage, phase, and frequency of the input

power is as specified on the welder nameplate.

Gain access to the input reconnect panel by removing

the right case side of the CV-300 (side nearest to the

Power switch.)

Have a qualified electrician connect the input leads to

L1, L2, and L3 of the input reconnect panel in accor-

dance with the National Electrical Code, all local

codes, and the connection diagram located on the

inside of the right case side. Use a three phase line.

The frame of the welder must be grounded. A ground

terminal marked with the symbol

located on the

base of the machine is provided for this purpose. See

the National Electrical Code for details on proper

grounding methods.

Fuse the input circuit with the recommended super lag

fuses.

Choose an input and grounding wire size

according to local codes or use the following table.

"Delay type"

1

circuit breakers may be used in place of

fuses. Using fuses or circuit breakers smaller than rec-

ommended may result in "nuisance" tripping from

welder inrush currents even if not welding at high cur-

rents.

ELECTRIC SHOCK can kill.

Only qualified personnel should

perform this installation.

Turn the input power OFF at the discon-

nect switch or fuse box before working on

this equipment.

• Turn the Power switch on the CV-305 “OFF” before con-

necting or disconnecting output cables, wire feeder or

remote connections, or other equipment.

• Do not touch electrically hot parts.

• Always connect the Idealarc CV-305 grounding terminal

(located on the welder base near the reconnect panel) to a

good

electrical earth ground.

WARNING

RECOMMENDED INPUT WIRE AND FUSE SIZES

Input

Voltage /

Frequency

208/60

230/60

460/60

575/60

Input

Ampere

Rating on

Nameplate

51

48

24

20

Type 75°C

Copper

Ground Wire in

Conduit AWG

(IEC) Sizes

8 (10mm2)

10 (6mm2)

10 (6mm2)

10 (6mm2)

Fuse

(Super Lag)

or Breaker

Size

70

60

40

40

Type 75°C

Copper Wire

in Conduit

AWG (IEC)

Sizes

6 (16 mm2)

6 (16 mm2)

10 (6mm2)

1Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit

breakers which have a delay in tripping action that decreases as the magni-

tude of the current increases.

CAUTION

Re

tu

rn

to

Se

ct

io

n

T

O

C

Re

tu

rn

to

Se

ct

io

n

T

O

C

Re

tu

rn

to

Se

ct

io

n

T

O

C

Re

tu

rn

to

Se

ct

io

n

T

O

C

Re

tu

rn

to

M

a

st

e

r

T

O

C

Re

tu

rn

to

M

a

st

e

r

T

O

C

Re

tu

rn

to

M

a

st

e

r

T

O

C

Re

tu

rn

to

M

a

st

e

r

T

O

C

Advertising