The output voltage cannot be preset, Troubleshooting & repair, Caution – Lincoln Electric IDEALARC CV-305 User Manual
Page 41
FUNCTION PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
The output voltage cannot be pre-
set.
1.
Place
the
remote
switch
in
machine control. If normal oper-
ation is restored then the remote
control
unit
may
be
faulty.
Check or replace.
2.
If an error message is displayed
see
1.
Check the output control (R2)
and associated circuitry.
2.
The meter board may be faulty.
Replace.
3.
The
control
Board
may
be
faulty. Replace.
The weld output terminals are
always electrically “hot”.
1.
Remove any control cable that
may be connected to the 14 pin
amphenol.
If the problem is
resolved the fault is in the con-
trol cable or the wire feeder.
2.
If some open circuit voltage is
present (over 3 VDC.) after per-
forming Step #1 then the prob-
lem
is
within
the
CV305.
Contact
your
local
Lincoln
Authorized Field Service Facility.
1.
Check
for
an
internal
short
between leads #2 and #4. See
wiring diagram.
2.
Perform the
3.
The
snubber
board
may
be
faulty. Replace.
TROUBLESHOOTING & REPAIR
F-9
F-9
IDEALARC® CV-305