Troubleshooting & repair – Lincoln Electric IDEALARC CV-305 User Manual

Page 61

Advertising
background image

TROUBLESHOOTING & REPAIR

F-29

F-29

IDEALARC® CV-305

5ms

20V

0 Volts

CH1

This is a typical output voltage generated

from a properly operating machine.

Note

that each vertical division represents 20

volts and that each horizontal division repre-

sents 5 milliseconds in time.

Note: Scope probes connected at machine

high inductance output terminals.

Volts/Div . . . . . . . . . . . . . . . . . .20 V/Div.

Horizontal Sweep

. . . . . . . . . .5 ms/Div.

Coupling . . . . . . . . . . . . . . . . . . . . . .DC.

Trigger

. . . . . . . . . . . . . . . . . . . .Internal.

SCOPE SETTINGS

NORMAL OPEN CIRCUIT WELD VOLTAGE WAVEFORM

NO LOAD - OUTPUT CONTROL AT MAXIMUM