Verify

The Verify preference allows you to choose whether
the Logicube Omniclone Xi™ verifies the data
copied to the Target drive. Verify also scans the
Target drives for bad or weak sectors. With Verify
activated, data written to the Target is read back
sector by sector and compared against the original
data on the Master. If a bad sector of data is
detected, the cloning process is aborted.

Verify Settings

No Verify (Default) - No data verification is
performed.

1% Verify - Only the first 1% of the data sectors
are verified. This is faster but less thorough than
using the All setting.

100% Verify - Every data sector on the Target
drive to which data has been written is checked.

NOTE: Logicube strongly recommends against
using a hard drive that has been shown to have bad
sectors as new defects are likely to develop.