Paradyne 392xPLUS User Manual

Page 199

Advertising
background image

COMSPHERE 392xPlus Modems

5-14

November 1996

3920-A2-GN31-30

Table 5-2

(9 of 9)

392x

Plus AT Commands

AT

Command

DCP LCD

Command

Sequence

Description

\N

n

Error Control Mode.

\N0

Buffer Mode.

\N1

Direct Mode.

\N2

MNP or Disconnect.

\N3

MNP or Buffer.

\N4

V.42/MNP or Disconnect.

\N5

V.42/MNP or Buffer.

\N6

LAPM or Disconnect.

\N7

LAPM or Buffer.

Configure\Edit\
V42/MNP/Buffer

\Q

n

Flow Control of DTE, Flow Control of Modem.

Flow Control

Flow Control

of DTE:

of Modem:

\Q0

Disable

Disable

\Q1

XON/XOFF

XON/XOFF

\Q2

CTS to DTE

Disable

\Q3

CTS to DTE

RTS to Mdm

\Q4

XON/XOFF

Disable

\Q5

Disable

XON/XOFF

\Q6

Disable

RTS to Mdm

Configure\Edit\
V42/MNP/Buffer

\T

n

No Data Disconnect Timer.

\T0

Disable.

\Tn

Where

n is a value from 1 to 255 in 1-minute increments.

Configure\Edit\
Line Dialer

NOTE: The factory default value is country dependent.

\X

n

XON/XOFF Passthrough Flow Control.

\X0

Disable.

\X1

Enable.

Configure\Edit\
V42/MNP/Buffer

%A

n

Error Control Fallback Character.

%An

Where

n is an ASCII value from 0 to 127. Factory default is 013

ASCII.

Configure\Edit\
V42/MNP/Buffer

%C

n

MNP5 Data Compression.

%C0

Disable.

%C1

Enable.

Configure\Edit\
V42/MNP/Buffer

I

H

n

V.42bis Compression.

I

H0

Disable.

I

H1

Enable (Transmit (TX) only).

I

H2

Enable (Receive (RX) only).

I

H3

Enable (Transmit (TX) and Receive (RX)).

Configure\Edit\
V42/MNP/Buffer

Advertising