Technical specifications, Technical specifications for 392x plus modems – Paradyne 392xPLUS User Manual

Page 24

Advertising
background image

Introduction

1-13

3920-A2-GN31-30

November 1996

Technical Specifications

Table 1-2 shows the technical specifications for the 392xPlus modems.

Table 1-2

(1 of 2)

Technical Specifications for 392x

Plus Modems

Specifications

Description

APPROVALS

Model 3920

Plus, 3921Plus, and

COMSPHERE 3000 Series Carrier

Refer to the product labeling or contact your service representative.

COMPATIBILITY

Leased-Line Modulations:

Paradyne V.34 (33,600, 31,200 bps)
CCITT V.34 (28,800, 26,400, 24,000, 21,600, 19,200, 16,800, 14,400,

12,000, 9600, 7200, 4800, 2400 bps)

Paradyne V.32 terbo (19,200, 16,800 bps)
CCITT V.32bis (14,400, 12,000, 9600, 7200, 4800 bps)
CCITT V.32 (9600, 4800 bps)
Paradyne Trellis Multipoint (19,200, 14,400, 9600, 7200, 4800,

2400 bps)

CCITT V.22bis (2400 bps)
CCITT V.27bis (4800, 2400 bps)
CCITT V.33 (14,400, 12,000 bps)
CCITT V.29 (9600, 7200, 4800 bps)
Paradyne Point-to-Point Diagnostic (2400 bps)

Dial-Line Modulations:

Paradyne V.34 (33,600, 31,200 bps)
CCITT V.34 (28,800, 26,400, 24,000, 21,600, 19,200, 16,800, 14,400,

12,000, 9600, 7200, 4800, 2400 bps)

Paradyne V.32 terbo (19,200, 16,800 bps)
CCITT V.32bis (14,400, 12,000, 9600, 7200, 4800 bps)
CCITT V.32 (9600, 4800 bps)
CCITT V.22bis (2400 bps)
CCITT V.22 (1200 bps)
CCITT V.23 (1200, 600 bps)
CCITT V.21 (300 bps)
Bell 212A (1200 bps)
Bell 103J (300 bps)
Paradyne Point-to-Point Diagnostic (2400 bps)

ENVIRONMENT

Operating Temperature

32

°

F (0

°

C) to 122

°

F (50

°

C)

Relative Humidity

5% to 90% (noncondensing)

Shock and Vibration

Withstands normal shipping

Storage Temperature

– 4

°

F (–20

°

C) to 158

°

F (70

°

C)

DTE INTERFACE

25-pin D-subminiature connector

EIA-232-D/CCITT V.24

MODEL 3920

Plus POWER SUPPLY

AC POWER REQUIREMENTS

100 to 250 Vac, 50 to 60 Hz

Advertising