Paradyne 392xPLUS User Manual

Page 209

Advertising
background image

COMSPHERE 392xPlus Modems

5-24

November 1996

3920-A2-GN31-30

Table 5-3

(9 of 12)

392x

Plus S-Registers

S-Register

DCP LCD

Command

Sequence

Description

S74

Network Position Identification. Register identifies each modem as either a
control or tributary modem.

Register has the following values:

0 = Tributary
1 = Control

The factory setting is Tributary.

Configure\Edit\
Misc

S75

Network Management Address. Register determines the modem’s network
address. This address is used when accessing the modem from the 6700
Series NMS.

Enter a value from 0 (network address 001) to 255 (network address 256).
The factory setting is 0.

Configure\Edit\
Dial

S76

V.32bis Autorate (Dial Line). Register determines if Autorating is used on dial
lines when connected in V.32bis mode.

Register has the following values:

0 = Enable
1 = Disable

The factory setting is Enable.

Configure\Edit\
Dial Line

S78

V.32bis Automode (Dial Line). Register allows the modem (when operating on
dial lines) to automatically detect and connect to the remote modem’s
modulation scheme.

Register has the following values:

0 = Enable
1 = Disable

The factory setting is Enable.

Configure\Edit\
Dial Line

S82

V.32bis Autorate (Leased Line). Register determines if Autorating is used on
leased lines when connected in V.32bis mode.

Register has the following values:

0 = Enable
1 = Disable

The factory setting is Enable.

Configure\Edit\
Leased Line

S84

AT Command Mode. Register determines how the modem responds to valid
and invalid AT commands.

Register has the following values:

0 = Normal
1 = No ERROR
2 = No Strap or ERROR

The factory setting is Normal.

Configure\Edit\
DTE Dialer