Gain adjustment, Operating instructions, Parameters to be automatically set – Panasonic MINAS E-series User Manual

Page 133

Advertising
background image

133

[Gain Adjustment]

Gain Adjustment

Operating Instructions

(1) Set an operating pattern with Pr25.

(2) Shift load to a position where there will be no problem if the motor executes the operating pattern set with

Pr25.

(3) Do not enter a command.

(4) Activate Servo-ON.

(5) Start auto gain tuning.

Do so by using a console or PANATERM

®

.

For operating instructions with the console, see a next page.

(6) Adjust mechanical stiffness No. so that you can have desired response at a level that results in no vibration.

(7) If you have no problem with the result, write it into EEPROM.

Parameters to be automatically set

Auto gain tuning table

Pr10

1st position loop gain

Pr11

1st velocity loop gain

Pr12

1st velocity loop integration time constant

Pr13

1st speed detection filter

Pr14

1st torque filter time constant

Pr15

Velocity feed forward

Pr16

Feed forward filter time constant

Pr18

2nd position loop gain

Pr19

2nd velocity loop gain

Pr1A

2nd velocity loop integration time constant

Pr1B

2nd speed detection filter

Pr1C

2nd torque filter time constant

Pr.20

Inertia ratio

Pr30

2nd gain set-up

Pr31

Position control switching mode

Pr32

Position control switching delay time

Pr33

Position control switching level

Pr34

Position control switching hysteresis

Pr35

Position loop gain switching time

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

27

15

37

0

152

300

50

31

15

1000

0

152

1

10

30

50

33

20

32

18

31

0

126

300

50

38

18

1000

0

126

1

10

30

50

33

20

39

22

25

0

103

300

50

46

22

1000

0

103

1

10

30

50

33

20

48

27

21

0

84

300

50

57

27

1000

0

84

1

10

30

50

33

20

63

35

16

0

65

300

50

73

35

1000

0

65

1

10

30

50

33

20

72

40

14

0

57

300

50

84

40

1000

0

57

1

10

30

50

33

20

90

50

12

0

45

300

50

105

50

1000

0

45

1

10

30

50

33

20

108

60

11

0

38

300

50

126

60

1000

0

38

1

10

30

50

33

20

135

75

9

0

30

300

50

157

75

1000

0

30

1

10

30

50

33

20

162

90

8

0

25

300

50

188

90

1000

0

25

1

10

30

50

33

20

206

115

7

0

20

300

50

241

115

1000

0

20

1

10

30

50

33

20

251

140

6

0

16

300

50

293

140

1000

0

16

1

10

30

50

33

20

305

170

5

0

13

300

50

356

170

1000

0

13

1

10

30

50

33

20

377

210

4

0

11

300

50

440

210

1000

0

11

1

10

30

50

33

20

449

250

4

0

10

300

50

524

250

1000

0

10

1

10

30

50

33

20

557

310

3

0

10

300

50

649

310

1000

0

10

1

10

30

50

33

20

Stiffness Value

shows parameters that are set to a fixed value. A default setup stiffness is 4.

Name

Parameter

No.

Estimated load inertia ratio

Advertising