[Connections and Settings in Position Control Mode]

Connections and

Settings in Position

Control Mode

Command
pulse

× 2

1st numerator (Pr46)

*1

*1

Scaling factor (Pr4A)

Internal
command

F

f

+

(Resolution)

Feedback
pulse

To deviation counter

10000P/rev

Denominator (Pr4B)

2nd numerator (Pr47)

PrNo.

Parameter Name

Function/Content

Command pulse dividing multiplier (electronic gear) function

Purposes of Use

(1) To arbitrarily set rotation/motion of the motor per a unit input command

pulse.

(2) To increase apparent command pulse frequency, by using multiplier

function, when the pulse oscillation capacity (maximum frequency that can

be output) of the host is limited and thus required motor speed cannot be

obtained.

• Block Diagram of Dividing Multiplier Unit

A calculated value of a numerator shall be up to 2621440. Even though you

set a value greater than this upper limit, setting will be invalid. Note that

2621440 will be a numerator.

Selection of command multiplier dividing “numerator”

*1: Select 1 or 2 with command dividing multiplier input switching (DIV:CN X5 pin

6).

<Example of Setting>

It is essential that “the motor rotates once with command input (f) for resolution

of the encoder”, when the diving multiplier ratio = 1.

Thus, in order to rotate the motor once as an example when the encoder

resolution is 10000 P/r, you should enter f =5000 Pulse for double multiplier,

and f=40000 Pulses in 1/4 dividing.

Set Pr46, 4A and 4B so that internal command (F) after dividing multiplier will

be equal to resolution of the encoder (10000).

46

47

4A

4B

Numerator of 1st

command pulse ratio

Numerator of 2nd

command pulse ratio

Multiplier of numerator

of command pulse ratio

Denominator of

command pulse

ratio

1 -

10000

[10000]

1 -

10000

[10000]

0 - 17

[0]

1 -

10000

[10000]

DIV OFF

DIV ON

Select a 1st numerator (Pr46).

Select a 2nd numerator (Pr47).

Related to command pulse dividing multiplier function (Pr46, 47, 4A, 4B)

F = f x

Pr46 x 2

Pr4A

=10000

Pr4B

F: Number of internal command pulses for one rotation of the motor

f: Number of command pulses for one rotation of the motor

Standard Default Setup: [ ]

Resolution of Encoder

Example 1

Set command input (f) to

5000 per one rotation of

the motor

Example 2

Set command input (f) to

40000 per one rotation of

the motor

10000 (2500P/r x 4)

Pr 46 10000 x 2

Pr 4B 5000

Pr 46 2500 x 2

Pr 4B 10000

Pr 4A

0

Pr 4A

0

Range of

Settings

Advertising