Gain adjustment, Figure a, Figure c – Panasonic MINAS E-series User Manual

Page 139: Figure d, Figure e, Figure f figure g

Advertising
background image

139

[Gain Adjustment]

Gain Adjustment

*1 Delay time (Pr32) will be validated upon return from second gain to first gain.

*2 Definition of hysteresis (Pr34) is as illustrated in the figure below:

*3 If the condition that there is torque variation of 10% during 166

µs is included, setting should be

200.

10% / 166

µs = setting 200 x (0.05% / 166 µs)

*4 Resolution of the encoder

*5 When Pr31=10, delay time, level and hysteresis mean differently from usual cases (See Figure G).

Hysteresis

Level

(Pr33)

(Pr34)

0

H

L

<Caution>

Any lag in gain switching timing due to hysteresis (Pr34) is not reflected in the above figure.

Speed N

Figure A

Torque T

Level

Delay

1st gain

2

2

1

2

2

1

1

1

Command speed S

Figure C

Level

Delay

2nd gain

1st

1st

Speed N

Deviation pulse

Figure D

Level

Delay

2nd gain

1st

1st

Command speed S

Figure E

Delay

2nd gain

1st

1st

Speed N

Figure F

Figure G

Delay

2nd gain

1st

COIN

1st

When stopped

There is

command pulse

There is no command pulse

x Pr32 delay time

| Actual speed |<

Pr 33 level

| Actual speed | < (Pr33 level – Pr34 Hysteresis)

| Actual speed | < (Pr33 level – Pr34 Hysteresis)

1st gain

During operation

2nd gain

When stabilized

2nd gain

Close to stop

Only speed integration is 2nd
gain, while others are 1st gain.

Advertising