Connections and settings in position control mode, This represents a twisted pair cable. <remarks – Panasonic MINAS E-series User Manual

Page 77

Advertising
background image

77

[Connections and Settings in Position Control Mode]

Connections and

Settings in Position

Control Mode

240

14a

13a

12a

11a

15a

16a

10a

9a

8b

8a

1a

3a

2b

4a

PLC

F3YP14-ON/F3YP18-ON(Yokogawa Electric Corporation)

Driver

E-series

From PLC
I/O output

To PLC
I/O input

V+

GND

7.4k

7.4k

7.4k

220

220

4.7k

4.7k

4.7k

4.7k

4.7k

4.7k

PULS1

PULS2

SIGN1

SIGN2

OZ+

OZ-

GND

COM+

CL

SRV-ON

GAIN/TC

A-CLR

CCWL

CWL

ALM

COIN

BRKOFF

WARN

COM-

22

23

24

25

19

20

14

1

4

2

5

3

8

7

9

10

11

12

13

Origin proximity
sensor

CW limit sensor

CCW limit sensor

Origin line driver
input

Origin proximity
input

CCW limit input

CW limit input

5V power supply
for pulse output

CW pulse command
output

CCW pulse command
output

Deviation pulse clear
signal output

GND +5V

DC5V

power supply

GND +24V

DC24V

power supply

CW pulse
command
input

CCW pulse
command
input

Counter
clear input

Servo-ON
input

Servo alarm
output

Positioning
completing output

Brake release
output

Alarm clear
input

Phase Z
output

Warning output

Gain switching
input/torque limit
switching input

CW overtravel
inhibit input

CCW overtravel
inhibit input

Yokogawa Electric Corporation F3YP14-ON/F3YP18-ON

This represents a twisted pair cable.

<Remarks>

Advertising