Reference – Panasonic MINAS E-series User Manual

Page 169

Advertising
background image

169

[Reference]

Reference

command

2

mode

4

Readout of current speed

Received data

0

axis

checksum

2

4

Error code

Transmitted data

This command is used to read current speed (unit [r/min]).

An output value is 16 bits.

For the counter value, "-" indicates CW and "+" indicates CCW.

bit7

0 : Normal
1 : Error

6

5

4

3

2

1

0

3

axis

Data (current speed) L

H

Error code

checksum

2

4

command

2

mode

5

Readout of current torque output

Received data

0

axis

checksum

2

5

Error code

Transmitted data

This command is used to read current torque output (unit: to be converted as rated torque = 2000).

An output value is 16 bits.

bit7

0 : Normal
1 : Error

6

5

4

3

2

1

0

3

axis

Data (torque) L

H

Error code

checksum

2

5

command

2

mode

2

Readout of the feedback pulse counter

Received data

0

axis

checksum

2

2

Error code

Transmitted data

A current position of the feedback pulse counter is expressed by absolute coordinates from the start-up time.
For the counter value, "-" indicates CW and "+" indicates CCW.
The feedback pulse counter indicates a cumulative sum of pulses of the position detector, which corresponds to a position of
the motor that really moves.

bit7

0 : Normal
1 : Error

6

5

Command error

4

Command error

Command error

3

2

1

0

5

axis

Counter value L

H

Error code

checksum

2

2