Communications

command

2

mode

1

Readout of the command pulse counter

Received data

0

axis

checksum

2

1

Error code

Transmitted data

A current command position is expressed by absolute coordinates from the start-up time. (Cumulative sum of the number of
command pulses)
The counter value is 32 bits.
For the counter value, "-" indicates CW and "+" indicates CCW.

bit7

0 : Normal
1 : Error

6

5

Command error

4

3

2

1

0

5

axis

Counter value L

H

Error code

checksum

2

1

command

2

mode

0

Readout of status

Received data

0

axis

checksum

2

0

Error code

Transmitted data

The control modes are defined as follows:

bit7

0 : Normal
1 : Error

6

5

Command error

4

3

2

1

0

Status

bit7

6

5

CCW
Torque being output

4

CW
Torque being output

3

CCW
rotating

2

CW
rotating

1

Less than DB
permission speed

0

Torque being
limited

3

axis

Control mode

Status

Error code

checksum

2

0

0

1

2

High speed response positioning control mode

Internal velocity control mode

High function positioning control

Advertising