[Connections and Settings in Position Control Mode]

Connections and

Settings in Position

Control Mode

Parameters for Torque Limits

PrNo.

Parameter Name

Function/Content

• With this parameter set, maximum torque of the motor is limited in the driver.

• Normal specification allows torque about 3 times as large as rated torque, if in

an instant. We recommend that you limit the maximum torque with this param-

eter if the tripled torque might cause trouble to intensity of the motor load

(machine).

5E

1st torque limit set-

up

0 -

500

• You can give setting as a percentage

(%) value to rated torque.

• The right figure shows an example in

which it is limited to 150%.

• Pr5E limits the maximum torque of

both CW and CCW directions simulta-

neously.

Speed

200

100 (Rated)

(Rated)

100

200

300

Torque [%]

300 (Max.)

(Max.)

CW

CCW

When Pr5E=150

<Remarks>

With torque limit switching function enabled (Pr06=2), this parameter is a

value of the 1st torque limit.

<Cautions>

You cannot set to this parameter a value that exceeds a default setup value

with “Maximum Output Torque Setting” of the system parameter (i.e., factory

default parameters that cannot be changed through manipulation of

PANATERM

®

and console). A default setup value may differ depending on a

combination of a motor and driver. For detailed information, refer to “Setting

of 1st Torque Limit” on Page 45 of Preparation edition.

Parameters for Sequences

PrNo.

Parameter Name

Function/Content

• The parameter sets timing to output a positioning completion signal (COIN:CN

X5 pin 10) when movement of the motor (work) is complete after input of

command pulse ends.

• The positioning completion signal (COIN) is output when the number of pulses

of the deviation counter falls within

± (setting).

60

In-position range

0 -

32767

[10]

Standard Default Setup: [ ]

A basic unit of deviation pulse is

“resolution” of an encoder to be

used. Thus, in the case of E series,

it will be: 4 x 2500P/rev=10000

<Cautions>

1. Setting of too small a value to Pr60 might extend time before COIN signal

is output, or generate chattering during output.

2. Setting of “In-position range” does not affect precision of final positioning.

Range of

Settings

Range of

Settings

COIN

Deviation pulse

On

Pr60

Pr60