Conformance to ec directives/ul standards, Noise filter, Surge absorber – Panasonic MINAS E-series User Manual

Page 182

Advertising
background image

182

Noise Filter

When, one set of noise filters is installed in the power unit with two or more drivers, be sure to consult with the noise

filter manufacturer.

Surge Absorber

Install the surge absorber on the primary line of the noise filter.

<Note>

When conducting voltage-resistant test on the machine/equipment, remove the surge absorber.

Otherwise the absorber may be damaged.

Conformance to EC Directives/UL Standards

Circuit diagram

Manufacturer’s part No.

3SUP-HU10-ER-6

Manufacturer

Okaya Electric

Industries Co., Ltd.

Option Part No.

DV0P4160

Option Part No.

DV0P1450

Manufacturer

Okaya Electric

Industries Co., Ltd.

Manufacturer’s part No.

R•A•V-781BXZ-4

Advertising