[Preparations]

Preparations

Turn on the driver with the console connector connected to the driver, or connect the console connector to connec-

tor CN X6.

Determined by the setting
of parameter Pr01 in the
initial state of LED.

0.6 sec

To initialize the console, the display
comes on about 0.6 seconds respectively.

0.6 sec

0.6 sec

1 sec

------------------------Indicates ID number or the driver (data of parameter Pr00).

------Version of the microcomputer of the console is indicated.

(The indicated number differs according to the version of the microcomputer.)

------Indication of the initial state of LED

Using the Console

In parameter setting, set data after switching to parameter set mode.

MINAS

DIGITAL AC SERVO

MODE

SHIFT

SET

S

M

Display, LED (display in 6 digits)

Display of selected Driver ID No. (2 digits)
The value set up on Pr00 (shaft name) is ID No.
Parameter No. (2 digits) is displayed under “Parameter Setting” mode.

Setting Button:

Mode Selector Buttons: These buttons are used to select 6 different modes.
(1) MONITOR mode
(2) PARAMETER SETTING mode
(3) EEPROM WRITE mode
(4) NORMAL AUTO GAIN

TUNING mode

(5) AUXI FUNCTION mode
• Test run (JOG mode)
• Alarm clear
(6) COPING FUNCTION mode
• To copy parameters from the servo driver to the console.
• To copy parameters from the console to the servo driver.

This is used to shift the digits of data to be changed.

This is used to change the data and to execute parameter selection.
The numerical value increments by pressing ,
and it decrements by pressing .

This is to shift each mode, which was selected by the mode
selector button, to "EXECUTE" display.

Using the Console

The Initial State of the Display (7-Segment LED)