85

[Connections and Settings in Position Control Mode]

Connections and

Settings in Position

Control Mode

Check that alarm code LED does not flash? (It is out during normal operation).

It starts flashing in case of an alarm.

An alarm code (refer to pages 145 to 148) indicates the alarm code number

by the number of flashes of orange and red lights.

Orange: 10 digit Red: 1 digit

Description

Color of

LED Status

The main power is turned ON. The driver is switched ON.

The LED flashes (for 1 second) when a warning is issued.

(Abnormal overload, regeneration, and fan rotation speed)

Alarm output.

(Example)

When overload (alarm code No.16) occurs and the motor stops:

The orange light flashes once and red one flashes 6 times.

Orange

1 sec.

Red

0.5 sec.

0.5 sec.

1 sec.

Red

0.5 sec.

Red

0.5 sec.

Red

0.5 sec.

Red

0.5 sec.

Red

0.5 sec.

0.5 sec. 0.5 sec. 0.5 sec. 0.5 sec.

After 2 seconds

Green

Orange

Red

(2) Check LED status.

(3) Setting the parameter

Prepare for a personal computer and “PANATERM

®

”. Or prepare for a console.

(4) Enter a command that matches the control mode.