Preparations, Pr5e 1st torque limit set-up – Panasonic MINAS E-series User Manual

Page 45

Advertising
background image

45

[Preparations]

Preparations

1-phase

100V

300

330

330

300

1-phase/

3-phase

200V

Driver
power

Motor model

Parameter 5E standard

default setup value

MUMA5AZP1

MUMA011P1

MUMA021P1

MUMA5AZP1

MUMA012P1

MUMA022P1

MUMA042P1

Notes in Replacing Motor

The upper limit value of Pr5E 1st torque limit setting-up range is automatically decided by connecting the motor to

the driver. Therefore, Pr5E setup value must be rechecked when replacing the motor.

x1

x3

x4

x5

x6

STATUS

ALM CODE

Ex.)

Pr5E

Setting-up range: 0 - 300%
When the setup value is 100%,

0.16N•m

× 100%=

Before replacing motor

x1

x3

x4

x5

x6

STATUS

ALM CODE

torque limit value

0.16N•m

Rated torque

0.16N•m

MKDET1505P

MUMA5AZP1

Pr5E

Setting-up range: 0 - 300%
If the setup value remains unchanged as 100%,

0.32N•m

× 100% =

After having replaced

torque limit value

0.32N•m

Rated torque

0.32N•m

MKDET1505P

MUMA012P1

For torque limit value 0.16N•m,
set it to 50% (0.32N•m

× 50% =

0.16N•m).

Pr5E 1st Torque Limit Set-up

<Note>

Where the motor model was changed, the maximum value of Pr5E may vary eventually. Therefore, recheck

the setup value and re-set it as necessary.

1. When replacing the current motor with motor of the same model

Pr5E 1st torque limit value to be set up after motor replacement is the value that has been written in the driver

before the replacement. Particularly, the setup value needs no change.

Before replacing motor

After having replaced

Ex.)

50W motor had been used

with 100-% torque limit.

In the case the current 50W motor is replaced with

another 50W motor of the same output capacity, Pr5E

setup value remains unchanged as 100-% torque limit.

• Pr5E 1st torque limit can’t be set up in excess to the value that was set up before shipping, under “Maximum

Torque Setting” of the system parameters. The setup value under “Maximum Torque Setting” is the same as the

standard default setup value.

• The system parameters are those before shipping from the shop which can’t be changed in PANATERM

®

and the

console.

2. When limiting motor torque

Pr5E 1st torque limit is set up at percentile (%) value against the rated torque. In the case the current motor

was replaced with another motor different from it in the motor series or W-number, Pr5E setup value must be

re-set up because the rated torque value differs from that of the motor before being replaced.

Before replacing motor

After having replaced

Ex.)

50W motor had been used

with 100-% torque limit.

In the case the current motor is replaced with 100W motor,

must be re-set at 100-% torque limit to 100W motor.

When limiting 100W motor torque with the same torque as 50W motor, set up the Pr5E 1st torque

limit at 50.