0 technical data – Baxi Potterton Gold HE A Range User Manual

Page 10

Advertising
background image

10

4.0 Technical Data

© Baxi Heating UK Ltd 2008

4.1

Gold Combi 24, 28 & 33 HE

A

Flue Terminal

Diameter

100mm

Dimensions

Projection

125mm

Outercase Dimensions
Casing Height

- 780mm

Overall Height Inc Flue Elbow

- 965mm

Casing Width

- 450mm

Casing Depth

- 345mm

Central Heating Primary Circuit
Pressures

bar

Safety Discharge

3

Max Operating

2.5

Min Operating

0.5

Recommended Operating Range

1-2

DHW Circuit

bar

Pressures
Max Operating

8

Min Operating

0.15

Flow Rates

(24)

(28)

(33)

l/min l/min

l/min

DHW Flow Rate
@ 30

o

C Rise

11.43

13.3

15.7

DHW Flow Rate
@ 35

o

C Rise

9.8

11.5

13.5

Min Working
DHW Flow Rate

2

2

2

Pump
Available Head

See graph below

Expansion Vessel

- (For Central Heating

only. Integral with appliance)

bar

Min Pre-charge Pressure

0.5

(24,28)

(33)

Max Capacity of

litre

litre

CH System

125

155

Primary Water Content
of Boiler (unpressurised)

2.5

2.8

Connections

copper tails

Gas Supply

-

22mm

Central Heating Flow

-

22mm

Central Heating Return

-

22mm

Cold Water Mains Inlet

-

15mm

DHW Flow

-

15mm

Pressure Relief Discharge

-

15mm

Temperatures
C.H. Flow Temp

(adjustable)

25°C to 80°C

max

(± 5°C)

D.H.W. Flow Temp

(adjustable)

35°C to 60°C

max

(± 5°C)

dependent upon flow rate

NOx Class

5

0

200

400

600

800

1000

1200

0.5

1

1.5

2

2.5

3

3.5

4

Metre (wg)

Flow Rate (l/h)

Pump - Available Head

0

5

5.5

4.5

Clearances
Above Casing

200 mm Min

Below Casing

200 mm Min

Front

450 mm Min

(For Servicing)

Front

5 mm Min

(In Operation)

L.H. Side

5 mm Min

R.H. Side

5 mm Min

(In Operation)

Heat Input CH (Net)

Max

Min

24 model

kW

20.5

7

28 model

kW

24.7

9

33 model

kW

28.9

9.7

Heat Output CH (Non-Condensing)

Max

Min

24 model

kW

20

6.8

28 model

kW

24

8.7

33 model

kW

28

9.4

Electrical Supply

230V~ 50Hz

(Appliance must be connected to an
earthed supply)

Power Consumption

155W (24 & 28 model) 160W (33 model)

Electrical Protection

IPX0D

Internal Fuse Rating

F2L

Appliance Category

CAT I

2H

Inlet Pressure (Natural Gas - G20)

mbar

20

Injector (Natural Gas - G20)

7.5mm (24&28 model)

12mm(33 model)

Appliance Type

C

13

C

33

C

53

Heat Output CH (Condensing)

Max

Min

24 model

kW

21

7.4

28 model

kW

25.9

9.5

33 model

kW

30.3

10.2

Heat Input DHW (Net)

Max

24 model

kW

24.7

28 model

kW

28.9

33 model

kW

34

Heat Output DHW

Max

24 model

kW

24

28 model

kW

28

33 model

kW

33

Max Gas Rate

(Natural Gas - G20)
(After 10 mins)

24 model

m

3

/h

2.61

28 model

m

3

/h

3.1

33 model

m

3

/h

3.6

Condensate Drain
To accept 21.5mm (

3

/

4

in) plastic waste pipe

Heat Input CH (Gross)

Max

Min

24 model

kW

22.7

7.8

28 model

kW

27.4

10

33 model

kW

32.1

10.8

Heat Input DHW (Gross)

Max

24 model

kW

27.4

28 model

kW

32.1

33 model

kW

37.7

External Fuse Rating

3A

The efficiency is 91.1% (all models)

This value is used in the UK Government’s Standard

Assessment Procedure (SAP) for energy rating of

dwellings. The test data from which it has been

calculated has been certified by 0087.

SEDBUK Declaration

Weights (kg)

(24)

(28)

(33)

Packaged Boiler Carton 48.6

49.2

51

Installation Lift Weight

43.6

44.2

46

Advertising