14.0 Changing Components

© Baxi Heating UK Ltd 2008

14.18

Plate Heat Exchanger (Fig. 98)

1. Drain the boiler primary circuit and remove the gas valve

as described in section 13.22.

2. While supporting the heat exchanger undo the screws

securing it to the brass manifolds.

3. Withdraw the heat exchanger upwards, taking care not to

damage any wires or controls.

Seals

4. There are four rubber seals between the manifolds and

heat exchanger which may need replacement.

5. Ease the seals out of the manifold. Replace carefully,

ensuring that when the seal is inserted into the manifold it is

parallel and pushed fully in.

6. When fitting the new heat exchanger note that the left

hand location stud is offset towards the centre more than the

right hand one.

7. Reassemble in reverse order.

14.19

Diverter Valve - Motor Unit & Assembly
(Figs. 99 & 100)

1. To replace the motor unit, disconnect the multi-pin plug.

2. Pull off the retaining clip and remove the motor unit.

3. The motor unit can now be replaced, or the valve

assembly removed.

4. Drain the primary circuit and draw off any hot water once

the isolating taps are closed.

5. Remove the spring clip retaining the bypass pipe to the

rear of the assembly and under the flow pipe nut at the left

hand side.

6. Undo the nuts on the tap rail under the boiler. Remove

the screws securing the valve assembly to the boiler bottom

panel and plate heat exchanger.

7. Remove the valve assembly. Examine any seals or washers,

replacing if necessary. Transfer the DHW NTC to the new

valve and reassemble in reverse order.

Plate Heat Exchanger

Rubber Seal

Fig. 98

Motor Unit

Multi-pin Plug

Retaining Clip

Valve

Assembly

Spring Clip

Bypass Pipe

Securing Screw

Fig. 99

Fig. 100

LH Location Stud

Pressure Sensor

Advertising