13.0 Servicing

© Baxi Heating UK Ltd 2008

13.1

Annual Servicing (Cont)

9. Undo the nut on the gas inlet pipe to the venturi (Fig. 77)

and pull the sensing pipe off the fan.

10. Disconnect the electrode leads, noting their position,

and the fan electrical plugs.

11. Undo the four nuts retaining the combustion box cover

to the heat exchanger.

12. Carefully draw the fan, collector and cover assembly

forward, being careful to retain the injector in the venturi

(Figs. 76 & 77).

13. Clean any debris from the heat exchanger and check

that the gaps between the tubes are clear.

14. Inspect the burner, electrodes and insulation, cleaning or

replacing if necessary. Clean any dirt or dust from the air

box.

15. Reassemble in reverse order.

NOTE: The sensing pipe must be reconnected to the

fan, not the venturi.

DHW Filter (Fig. 79)

16. If the flow of domestic hot water is diminished, it may

be necessary to clean the filter.

17. Initially check the cold water inlet tap filter.

18. Turn the tap off and draw off from a hot tap. Undo the

blanking cap and remove the threaded bush (Fig. 78).

19. Extract the filter and rinse thoroughly in clean water.

Reassemble and check the flow. If required clean the

restricter filter as described below.

20. Pull off the Hall Effect sensor. Undo the restricter from

the inlet/return manifold (Fig. 79).

21. Rinse the filter thoroughly in clean water and reassemble

in reverse order.

22. Turn the selector switch fully anticlockwise against the

spring pressure to the reset position and hold for 5 seconds

to reset the boiler.

23. Complete the relevant Service Interval Record section of

the Benchmark Commissioning Checklist at the rear of this

publication and then hand it back to the user.

Fig. 76

Cold Water

Inlet Tap

Blanking

Cap

Threaded

Bush

Fig. 78

Fig. 77

Hall Effect

Sensor

Hydraulic Inlet

Assembly

Fig. 79

Gas Inlet Pipe

Venturi

Injector

Restricter

Fan, Collector and Cover

Assembly

Filter

Electrode

Leads

4 ± 0.5

10 ± 1

7.5 ± 1

Electrode Position

Viewing Window

Burner

Advertising