0 fault finding – Baxi Potterton Gold HE A Range User Manual

Page 56

Advertising
background image

56

18.0 Fault Finding

© Baxi Heating UK Ltd 2008

E20 or E50 - Temperature sensors faulty.
Cold resistance approximately
10kΩ @ 25° C (DHW and CH sensors)
20kΩ @ 25° C (Flue sensor)
(resistance reduces with increase in temp.)

E28 - Incorrect PCB fitted

NO

E

Replace sensor or PCB (E28)

Gas at burner

Ensure gas is on and purged

Replace PCB

Replace gas valve

PCB - X3 connector is 230V AC across

terminals 1 & 2

YES

NO

NO

F

Replace PCB

G

Check and correct if necessary
1. Ignition electrode and lead
2. Electrode connection
3. Spark gap and position

YES

NO

Replace igniter

YES

H

YES

1.

Ensure that the Hall Effect Sensor is in position.
Check the connection between the PCB - X400
connector terminals 3,6,7 and the electronic sensor

Check the voltage between red wire and blue
wire is more than 5V DC

NO

Replace PCB

Check and correct the connection of the

tube between the venturi and gas valve

Replace Hall
Effect Sensor

YES

1.

2.

Voltage at PCB - X2 connector is at
least 100V DC across terminals 2 & 5
(Note: from multimeter connect
‘common’ to 2 & ‘volts’ to 5).
Check wiring

4 ± 0.5

10 ± 1

7.5 ± 1

Electrode Position

Viewing Window

Burner